In an ALS2 precious-metals recovery plant, reactor agitators keep electronic waste and process liquids evenly mixed while the acidless separation system works through its treatment stages. Seals protect the drive assembly, bearings and surrounding equipment from moisture, dust and process material. Their condition has a direct effect on throughput, energy use and operator safety.

A practical maintenance programme should combine routine observation with planned inspections during production stoppages. The correct interval depends on reactor loading, batch frequency, solids content, operating temperature, seal design and the quality of installation. The equipment manual and site risk assessment should always take priority over a generic calendar.

For Australian recyclers, local operating conditions can influence the schedule. A facility in Melbourne may face damp winter conditions, while a plant in Perth may deal with fine dust and high summer temperatures. Sites in regional Queensland or Western Australia may need to carry critical spares because specialist technicians and replacement components can take longer to reach the plant.

The ALS2 approach reduces reliance on aggressive acids, but acidless processing does not mean maintenance-free operation. Abrasive fragments, copper-rich material, dust from shredding, fluctuating batch weights and repeated start-stop cycles can still affect an agitator shaft, coupling, gearbox and seal. A documented inspection routine helps identify gradual wear before it becomes an unplanned shutdown.

Why Agitator And Seal Care Matters

The agitator establishes the movement needed for consistent contact between the feed and the separation medium. A bent shaft, worn impeller or loose coupling can create uneven circulation, dead zones and higher motor load. These symptoms may appear as longer processing times, inconsistent recovery results or unexplained changes in electrical consumption.

Seal failure presents a different risk. A leaking seal can allow process liquid into the bearing housing or drive area, while a damaged external seal can permit dust and moisture to enter. Either condition can accelerate bearing wear, contaminate lubricant and create a housekeeping problem around the reactor.

Maintenance teams should record baseline operating information when the reactor is performing correctly. Useful records include motor current, gearbox temperature, vibration, seal leakage, batch duration and the appearance of the processed material. Comparing later readings with this baseline is more reliable than relying on a single alarm or visual check.

Daily And Weekly Checks

Before each shift, operators should inspect the area around the reactor for unusual liquid, dampness, deposits, loose guards or material collecting around the shaft. A small amount of expected seepage may be acceptable for a particular seal arrangement, but a new drip pattern, spray or visible stream requires prompt assessment. The exact acceptance limit should come from the equipment supplier.

During operation, listen for changes in sound and observe the drive for excessive movement. Knocking, squealing, cyclic vibration or a fluctuating motor load can indicate an obstruction, misalignment, damaged impeller or developing bearing problem. Operators should never reach through a guard or attempt to clear material while the agitator is running.

At least weekly, clean accessible surfaces and inspect fasteners, guards, coupling covers, lubricant levels and cable glands. Check that the shaft rotates without visible wobble when the equipment is isolated and released for inspection. On dusty recycling lines, cleaning should avoid forcing debris past a seal or into an electrical enclosure.

Every check should be entered in a maintenance log with the date, batch conditions, findings and action taken. Photographs can be valuable for tracking a slowly increasing leak or a change in residue around the seal. Australian sites should align this routine with their documented isolation, permit-to-work and work health and safety procedures.

Monthly And Quarterly Inspection

A monthly inspection can include a closer examination of the agitator shaft, impeller attachment, coupling, gearbox mounting and reactor cover. Look for fretting, corrosion, cracked welds, loose hardware and signs that the impeller has contacted the vessel. Contact marks may indicate excessive shaft deflection, incorrect clearance or material build-up.

Technicians should check vibration and temperature against the established baseline. A gradual rise is often more useful than an isolated high reading. If measurements are outside the site’s acceptable range, the reactor should be assessed before the next extended production run. Corrective work may involve alignment, fastener tightening, bearing inspection or removal of material trapped around the impeller.

Seal inspection should cover the stationary and rotating faces where accessible, along with O-rings, packing, gland components, flush lines and drain paths. Hardening, swelling, cuts, flattening and discolouration are signs that a seal may need replacement. Seal materials must be compatible with the actual ALS2 process chemistry, temperature and solids exposure rather than selected solely by size.

Quarterly servicing is a suitable point to review spare parts and maintenance history. Keep replacement seals, gaskets, fasteners and suitable lubricants in protected storage. A recycler near Sydney or Melbourne may have faster access to industrial suppliers, while a remote facility should allow additional lead time for freight and technical support.

Annual Shutdown And Condition Assessment

During an annual or major planned shutdown, isolate, lock and verify the reactor before removing guards or opening inspection points. Drainage, cleaning and residual-material controls should be completed according to the site procedure. The inspection should cover shaft straightness, impeller condition, coupling alignment, gearbox backlash, bearing condition and the integrity of the reactor cover.

The agitator shaft should be checked for runout using an appropriate measurement method. The impeller should be examined for erosion, distortion, cracks and loss of balance. Even modest imbalance can increase vibration and place additional load on seals and bearings. Any repair or welding should be assessed for its effect on balance, material compatibility and clearances.

Replace seals according to condition and manufacturer requirements, rather than automatically disturbing a serviceable assembly without a reason. However, a seal that has been removed during major work should generally be renewed if its design or condition makes reuse unreliable. Record the seal type, material, installation orientation and any required compression or setting dimensions.

After reassembly, confirm shaft alignment, guard fitment, lubrication and free movement before energising the drive. Run the reactor through a controlled test, first without process material where permitted, then under normal load. Record vibration, temperature, motor current and leakage so the new post-maintenance baseline is available for future inspections.

Adjusting The Schedule To Site Conditions

A calendar-based programme is useful, but operating severity should determine whether intervals are extended or shortened. High solids loading, abrasive feed, frequent batch changes and long daily operating hours justify closer inspections. A reactor used intermittently with clean feed may require less frequent intrusive work, provided condition monitoring remains stable.

Environmental factors also matter. A plant in Perth may need additional attention to dust exclusion and cooling during hot weather. In coastal areas, salt-laden air can affect exposed fasteners and motor components. In tropical parts of Queensland, humidity can increase the importance of enclosure checks, drainage and moisture control. These conditions should be reflected in the risk assessment and spare-parts strategy.

The schedule below provides a planning framework rather than a substitute for the ALS2 equipment documentation. “Inspect” means observe and record condition; “service” means carry out a planned technical check or adjustment under isolation; and “replace” means renew the component when inspection or service limits require it.

Maintenance frequency Agitator and drive focus Seal and reactor focus Typical record
Every shift Noise, movement, motor load and visible shaft behaviour Leakage, spray, residue and unusual moisture Operator checklist
Weekly Guards, coupling cover, fasteners, lubricant level and accessible cleanliness Seal housing, drain path and cable or pipe entry points Work log with photos if needed
Monthly Vibration, temperature, shaft and impeller condition O-rings, packing, flush arrangements and early wear signs Condition report
Quarterly Alignment indicators, mounting hardware, gearbox condition and spare-part review Seal material, compression, deposits and replacement readiness Planned maintenance record
Annually or at major shutdown Shaft runout, impeller balance, bearings, coupling and full drive assessment Seal renewal decision, cover integrity and post-repair leak test Shutdown report and new baseline

A useful programme also defines escalation points. Immediate isolation may be required for rapid leakage, exposed rotating parts, severe vibration, burning smells, sudden motor overload or evidence that the impeller is striking the vessel. Less urgent changes, such as a small increase in temperature, can be placed on a monitored work order when the risk assessment permits continued operation.

For Australian operations, maintenance timing should fit the production calendar and local logistics. A shutdown before the peak summer period can reduce heat-related stress at some sites, while a regional facility may coordinate inspections with scheduled freight, contractor travel or an annual compliance visit. Planning these activities together reduces downtime without postponing essential safety work.

A disciplined schedule protects the reliability of the ALS2 reactor and supports stable precious-metals recovery from electronic waste and WEEE streams. Download the relevant equipment records, assign inspection responsibilities and use measured condition data to refine each interval. For technical guidance on ALS2 applications and plant support, contact the project team through the ALS2Project website.