A Beginner’s Guide To Reading ALS2 Output Assay Results

Assay results turn a mixed recycling material into measurable information. They can show how much gold, silver, palladium, copper, or another target element is present in a sample, helping operators judge feed quality, process performance, and the value of recovered fractions.

For newcomers, an assay certificate can look more complicated than it is. Most of the important details are found in a few places: the sample description, analytical method, reported unit, detection limit, uncertainty, and quality-control notes. Reading these fields in the right order prevents misleading comparisons.

This is particularly important in electronic waste and WEEE recycling, where feedstock is heterogeneous. Two samples taken from the same shipment may contain different proportions of circuit boards, connectors, cables, plastics, and metals. A reliable interpretation therefore begins with sampling context, not with the highest number on the page.

What an assay result actually measures

An assay is an analytical measurement of the concentration of a substance in a defined sample. In precious-metals recycling, the result may be reported as a mass concentration, such as grams per tonne, or as a percentage of the sample’s total mass. The figure applies to the tested portion, not automatically to the entire material batch.

A result such as gold at 250 g/t means that the laboratory estimates 250 grams of gold in one metric tonne of the tested material. It does not mean that 250 grams will necessarily be recovered by the plant. Recovery depends on separation efficiency, losses in residues, particle size, liberation, moisture, and the operating conditions of the process.

Assay data may describe feed material, an intermediate stream, a concentrate, or a final residue. The same element can have a low concentration in the original e-waste and a much higher concentration in a processed fraction. Always identify the stream before judging whether a result is good or poor.

For context, the ALS2 project overview explains the project’s focus on acidless separation technology for precious-metals recovery from electronic waste and related recycling streams. This context matters because assay interpretation is most useful when connected to a complete material flow rather than viewed as an isolated laboratory number.

Start with units, basis, and element names

The most common precious-metals units are ppm, g/t, mg/kg, and percentage. For solid materials, ppm and mg/kg are numerically equivalent, while 1 g/t is also equal to 1 mg/kg. Therefore, 100 ppm, 100 mg/kg, and 100 g/t represent the same concentration in a solid sample, provided the same mass basis is used.

Percentages describe a larger concentration. One percent equals 10,000 ppm, so 0.1% equals 1,000 ppm. Confusing percent with ppm can produce an error by a factor of 10,000. Before comparing two certificates, convert all values to a common unit.

The basis may be wet, dry, as-received, or normalized. A wet-basis result includes moisture in the total sample mass, while a dry-basis result excludes it. If a sample contains substantial moisture, the dry-basis concentration will generally be higher. The certificate should state the moisture result or the conversion used.

Element names also deserve attention. “Au” refers to elemental gold, “Ag” to silver, “Pd” to palladium, and “Pt” to platinum. A laboratory may report an element directly or report a compound equivalent, such as an oxide. Do not compare an elemental result with an oxide result without confirming the reporting convention.

Read the certificate in the right order

Begin with the sample identification, collection date, sampling location, and material description. A result labelled “PCB concentrate” cannot be fairly compared with one labelled “mixed WEEE fines” unless the differences in composition and preparation are understood. Check whether the sample was composite or grab-sampled, because a composite usually represents several increments while a grab sample represents one point in the material.

Next, find the analytical method. Fire assay, inductively coupled plasma methods, atomic absorption, X-ray fluorescence, and other techniques have different strengths. Some methods are suited to high concentrations; others are useful for multi-element screening or rapid process control. The method should be appropriate for the element and concentration range being measured.

Then examine the result column, units, and qualifiers. A value preceded by “<” is below the laboratory’s reporting limit, not necessarily zero. A result marked “ND” generally means “not detected,” but the exact meaning depends on the laboratory’s definitions. Flags such as “estimated,” “over range,” or “diluted” may indicate that the result needs special interpretation.

Certificate item What it tells you Why it matters
Sample ID and description Which material was tested Prevents comparison of different streams
Basis Wet, dry, or as-received mass Changes the apparent concentration
Analyte Element or compound measured Confirms what the number represents
Unit ppm, g/t, mg/kg, or % Allows valid conversion and comparison
Method How the laboratory measured it Indicates suitability and limitations
Detection or reporting limit Lowest reliably reported range Explains non-detects and censored values
Uncertainty or tolerance Expected measurement variation Helps distinguish meaningful differences
Quality-control status Whether checks passed Supports confidence in the result

Understand detection limits and uncertainty

A detection limit is the lowest concentration at which an analytical method can reliably identify an analyte. A reporting limit may be higher because the laboratory applies additional criteria before publishing a quantitative value. These limits depend on the sample matrix, dilution, instrument, and preparation procedure.

If palladium is reported as “<5 g/t,” the correct interpretation is that the concentration is below 5 g/t under that test, not that the material contains no palladium. For calculations, teams should document how non-detects are handled. Using zero, half the reporting limit, or the reporting limit itself can lead to different estimates, so the chosen rule should be consistent.

Uncertainty describes the likely range around a measured value. If gold is reported as 200 g/t with an uncertainty of ±20 g/t, the practical interpretation is different from a result of 200 g/t with an uncertainty of ±2 g/t. Two results of 200 and 210 g/t may be effectively indistinguishable when analytical variation is large.

Quality-control information can include blanks, duplicates, certified reference materials, spike recoveries, and calibration checks. A blank helps identify contamination, a duplicate tests repeatability, and a reference material checks whether the method produces a result close to a known value. A passing quality-control statement does not make a result infallible, but it provides important evidence of analytical reliability.

Convert grade into contained metal

To estimate contained metal, multiply the concentration by the mass represented. When the grade is in grams per tonne, the basic calculation is:

Contained metal in grams = grade in g/t × material mass in tonnes

For example, 180 g/t of gold in 2.5 tonnes of dry material indicates approximately 450 grams of gold before process losses. This is a theoretical contained amount, not a saleable or recovered quantity.

To estimate recovered metal, apply the recovery rate:

Recovered metal = contained metal × recovery percentage

If the process recovers 92% of the theoretical gold, 450 grams becomes 414 grams of estimated recovered gold. This calculation is only as good as the grade, mass, moisture correction, sampling, and recovery figure used.

A useful assay review also considers enrichment. Suppose a feed contains 20 g/t gold and a concentrate contains 180 g/t. The concentrate grade is nine times higher, but that does not prove that 90% of the gold entered the concentrate. The concentrate may represent only a small fraction of the original mass. A proper mass balance tracks feed, product, and residue together.

When several elements are reported, avoid adding their grades unless the units and analytical basis are compatible. High copper, nickel, or iron levels may influence sample preparation, dissolution, instrument response, or downstream separation. In electronic waste, matrix effects can be significant because plastics, ceramics, solder, and multiple base metals occur together.

Compare results without creating false trends

Trend analysis is valuable when the sampling method, preparation procedure, units, and laboratory method remain stable. A rising gold grade in successive concentrate samples may indicate improved concentration, but it may also result from a change in particle size, moisture, feed composition, or sample location.

Compare like with like: dry-basis results against dry-basis results, concentrate against concentrate, and the same element measured by comparable methods. Record the sample mass and moisture content as well as the assay grade. A higher grade in a smaller output stream may be commercially attractive, but its total contained metal may still be lower.

A balanced review uses grade, mass, recovery, and residue results together. The following simplified example shows why grade alone cannot define performance:

Stream Mass Gold grade Contained gold
Feed 10.0 t 50 g/t 500 g
Concentrate 1.5 t 280 g/t 420 g
Residue 8.5 t 8 g/t 68 g

The calculated output contains 488 grams, compared with 500 grams in the feed. The apparent difference may reflect sampling variation, analytical uncertainty, unmeasured streams, or actual process loss. The concentrate grade is much higher, but the mass balance is what reveals the wider process picture.

Practical checks before using the numbers

A beginner can build a dependable review routine by checking the certificate from top to bottom rather than jumping straight to the precious-metals column.

These checks are especially useful when assay data supports decisions about compact recovery plants or pilot-scale trials. The goal is not simply to find the most impressive grade. It is to establish whether the sample represents the process, whether the measurement is fit for purpose, and whether the calculated metal balance is credible.

Assay results become much more valuable when stored with sampling records, batch weights, process settings, and residue analyses. Over time, this creates a traceable dataset that can reveal changes in feed quality and separation performance more clearly than individual certificates.

Use this reading method on the next ALS2-related assay: identify the stream, verify the basis, check the method, calculate contained metal, and test the result against the complete mass balance. That disciplined approach turns laboratory output into practical evidence for safer and more efficient precious-metals recovery from electronic waste.